Choosing flooring for a restaurant kitchen in Madrid affects hygiene, slip risks, repairs and how long the kitchen must close. The decision involves more than the surface material: the base, falls towards drains, junctions and cleaning methods all matter. Both resin and ceramic tiles can work well when the complete system is correctly specified and installed. We explain this approach in our guide to choosing renovation materials for durability, maintenance and real cost.

What must a commercial kitchen floor provide?

Legal requirements and safety

Regulation (EC) No 852/2004 requires floor surfaces to be kept in good condition and to be easy to clean and, where necessary, disinfect. As a general rule, materials must be impervious, non-absorbent, washable and non-toxic; other materials may be accepted if their suitability is demonstrated to the competent authority. Adequate drainage must be provided where appropriate. The regulation neither requires resin nor prohibits ceramic tiles.

Spain’s Royal Decree 486/1997 requires workplace floors to be stable and non-slippery, without dangerous irregularities or slopes. Where Spain’s Technical Building Code, CTE DB-SUA, applies, Table 1.2 specifies Class 2 for wet internal areas with a gradient below 6%, and Class 3 at 6% or above. Class 3 is not automatically required in every kitchen. The responsible technical professional must establish how the code applies to the works. Grease contamination also requires a specific workplace risk assessment.

The CTE classes are established using a pendulum test. Its supporting document accepts UNE-EN 16165:2022, Annex C together with section AN.2 of the Spanish National Annex, as an equivalent alternative to the referenced test method. Ramp-test ratings such as R11 or R12 are not directly equivalent to CTE Class 2 or 3. Technical standards are not legislation in themselves; their enforceability depends on incorporation into regulations or contractual requirements.

Within Madrid city, the 2014 Public Health Protection Ordinance also applies. The wider framework includes Royal Decree 1021/2022 and regional legislation governing restaurant premises. The procedure for building works depends on their scope, any heritage protection and the authorised activity: Madrid Ordinance 6/2022 and Regional Law 17/1997 must be considered. Elsewhere in the Madrid region, consult the relevant local council.

Performance and construction details

The specification should address resistance to grease, cleaning chemicals, impact, abrasion, moisture and temperature changes. Fewer joints can simplify maintenance, but necessary movement joints must remain.

Falls and drains should suit the water used in the kitchen, avoiding ponding or drainage routes that spread contamination. Coving, a curved junction between floor and wall, helps cleaning. It is a hygienic design solution, not a universally prescribed detail under the European regulation. An impervious floor finish does not automatically replace a waterproofing system within the floor construction.

Resin flooring: choose the right system

  • Epoxy: a rigid resin with mechanical and chemical performance that depends on its formulation. It can suit controlled conditions, but resistance to very hot water or thermal shock must not be assumed.
  • Polyurethane: some systems offer greater flexibility. A decorative polyurethane finish is not necessarily suitable for a commercial kitchen.
  • Polyurethane-cement: combines resin with cement-based components. Certain systems are designed for demanding chemical and thermal exposure, subject to thickness, surface finish and technical specifications.

A continuous surface and integrated junctions reduce places where dirt can collect. However, an excessively smooth finish can be slippery, while a highly textured finish requires more thorough scrubbing.

Before installation, moisture levels, substrate strength and adhesion must be checked. Grease must be removed and the base mechanically prepared. Rising moisture or moving cracks can cause the finish to detach. Some polyurethane-cement systems tolerate higher moisture levels, but they do not solve every damp problem.

Local repairs or a compatible replacement surface layer may be possible, although patches often remain visible. There is no reliable universal service-life figure for “resin flooring”. Ask for a documented expectation for the specified system and operating conditions, distinguishing surface renewal from full replacement. Inspect for wear, cracks and loss of texture.

Ceramic tiles: the tile is only part of the floor

Consider low-absorption technical porcelain or industrial ceramic tiles with documented suitability for the intended use. Selection must account for equipment loads, impacts, chemicals and slip resistance. A domestic tile is not suitable simply because it looks robust.

The adhesive must suit the substrate, tile size, moisture and temperatures, and installation should avoid voids beneath tiles. Grout, the material filling the joints between tiles, needs suitable chemical resistance and cleanability. Epoxy grout may be useful in demanding areas, but it does not replace flexible movement joints.

Damaged tiles can be replaced individually. Common weaknesses include deteriorated grout, loose tiles and cracking caused by impacts or movement. Keep spare tiles for repairs. A tiled floor can remain in service for many years, but its durability also depends on the adhesive, joints and substrate; a universal lifespan should not be promised.

Cleaning and disinfection: a suggested routine

  • Daily: remove food debris and spills, apply a compatible detergent, scrub, collect the dirty solution, rinse where required and disinfect according to the hygiene plan. Follow the specified dilution, contact time and rinsing instructions. Leave no standing water.
  • Weekly: clean more thoroughly beneath accessible equipment and around coving, joints and drains. Use separate cleaning tools for drains.
  • Periodically: inspect cracks, detached areas, seals, surface texture and drainage. Record defects and schedule repairs. Frequency should reflect use and the establishment’s food safety procedures.

On resin, check wear and brush compatibility; on tiles, pay particular attention to grout and junctions. Do not use acids, solvents, steam or pressure washing unless the flooring system permits them. Cleaning products must be compatible with both the floor and the establishment’s hygiene plan. Never mix cleaning chemicals.

How long will the kitchen need to close?

The following are planning estimates for a 30–60 m² kitchen, with equipment removed, normal access, temperatures around 20°C, a serviceable base and no major changes to building services. They are not guaranteed durations and exclude administrative procedures and procurement.

  • Disconnecting and removing equipment: allow 1–2 days, coordinating the necessary installers.
  • Removing existing flooring: 1–3 days. Keeping it is only an option after checking stability, adhesion, finished levels and compatibility.
  • Preparation and minor repairs: 1–3 working days. Drying is additional: from around 1–3 days for compatible rapid repair materials to several weeks where a conventional new base is needed or moisture problems are found.
  • Resin installation: approximately 2–4 days, including layers and waiting periods between applications.
  • Tile installation: approximately 2–4 days, plus 1–2 days for the necessary wait before grouting and the grouting work, depending on products.
  • Final curing: provisionally allow 3–7 days for typical resin systems and 4–7 days after grouting for a compatible tiled system. Longer periods may be necessary; the complete system’s data sheets take precedence.
  • Reinstalling equipment, cleaning and checks: allow a further 1–2 days once the floor has developed sufficient resistance.

For example, Sikafloor PurCem HS-21 specifies approximately 12 hours before pedestrian access and four days to full cure at 20°C. Being able to walk on the floor does not mean equipment can be dragged across it or intensive cleaning can begin. This illustrates curing times, rather than recommending that particular finish for your kitchen. Kerapoxy Easy Design specifies around 24 hours before light foot traffic and four days before use under its stated conditions.

Equipment installation must be approved for the actual loads, wheels and support points. Reopening also requires sufficient chemical resistance, completed cleaning and final checks. Moisture, new falls, drain alterations, low temperatures, insufficient ventilation, kitchen size and phased working can extend the closure. Do not simply add up a generic timetable without identifying the products and activities that can overlap.

If other restaurant areas are affected, also consider whether to renovate commercial premises while open or during a planned closure. Keeping part of the business open is only appropriate where operations and building work can be safely separated.

Resin versus ceramic tiles: comparison

Flooring systems for a commercial kitchen
Criterion Resin Ceramic tiles Key considerations
Hygiene A continuous surface helps Good with intact joints Both depend on cleaning and condition
Joints Fewer, but necessary joints remain More joints and junctions Detail seals and edges carefully
Slip resistance Texture specified as part of the system Factory-made surface finish Request relevant test results and assess grease risks
Thermal and chemical resistance Varies considerably by system Depends on tiles, adhesive and grout Check actual temperatures and substances
Repairs Patching or compatible resurfacing Individual tile replacement Resolve the underlying cause first
Maintenance Monitor surface wear Monitor joints and tiles Both require inspections
Relative cost Thickness and specialist installation can increase cost Removal work and specialist grout can increase cost Neither is always cheaper
Closure time Depends on layers and curing Depends on laying, adhesive and grout Compare complete work programmes

Which option makes more sense?

Start with operating and cleaning temperatures, grease exposure, loads, substrate condition, repairability and acceptable downtime. Compare quotations covering the same work, including equipment removal, waste disposal, falls, drains, junctions and maintenance. Include the business cost of closure.

An industrial resin system may suit a kitchen where reducing joints and creating continuous junctions are priorities. For demanding thermal exposure, a purpose-designed polyurethane-cement system is worth assessing.

Industrial ceramic tiles may suit a kitchen where individual replacement is a priority and a compatible adhesive and grout system is available. Neither option compensates for a defective base.

Checklist before appointing a contractor

  • Survey of the substrate, moisture and cracks.
  • Identified system, thicknesses, data sheets and test reports.
  • Compatibility with chemicals, temperatures and loads.
  • Drawings showing falls, drains, joints and junctions.
  • Separate dates for pedestrian access, equipment installation and full service.
  • Itemised quotation, exclusions and arrangements for unforeseen work.
  • Cleaning and maintenance instructions, spare materials and warranty terms.
  • Applicable administrative procedure and final checks of adhesion, finishes and drainage.

Planning to renovate your restaurant kitchen in Madrid? Explore our commercial premises renovation service in Madrid and tell us what you need. We can assess the existing floor, scope of work and closure planning before preparing a final quotation.

Sources and references

Sources checked on 31 October 2026. The following Spanish and EU references must be applied to the individual premises and scope of work. Most linked documents are in Spanish.

Important: the proposed flooring system and return-to-service timetable must be validated by a suitably qualified technical professional, the installer and, where applicable, the relevant municipal authority.

Need this service? See our Commercial Premises Renovations in Madrid page.