Before deciding where to position your salon’s backwash basins, check what the premises can accommodate. The most appealing location for daylight, privacy or proximity to styling stations may be far from a suitable drainage connection or require hot water equipment that does not fit the space available.

Installing salon backwash basins means coordinating the water supply, hot water system and drainage with the way your business will operate. A layout designed without these checks can lead to raised floors, less usable space or a system that struggles when several treatments take place at once.

This guide helps salon owners assess premises in Madrid before signing a lease, starting a fit-out or buying equipment. It provides general guidance: a suitably qualified professional or installer must confirm feasibility based on the building, the selected equipment and the applicable Spanish and local requirements.

What to check before planning the wash area

Cold and hot water: finding the connections is only the beginning

Identify the incoming water supply, meter, isolation valves and existing pipework. If hot water is already available, establish where it comes from, when it is available and what the system can deliver. An old connection does not demonstrate that it will meet the needs of a new salon.

The installer should assess both the condition of the system and its performance under demand. One tap working well on its own does not prove that two backwash basins will maintain their flow and temperature when used together. Increasing pipe sizes within the premises will not necessarily solve a restriction in the incoming supply.

Drainage: connection height matters as much as location

Locate the drainage stacks and usable branch connections. Establish their purpose, diameter and condition, and measure the connection level relative to the floor. Do not assume that any pipe behind a wall is suitable, or that a rainwater stack can accept wastewater from the salon.

Measure the distance along the route the pipe can actually take, including obstacles and changes of direction. A connection that looks close on a floor plan may be unsuitable if it is too high or a beam obstructs the route. Concealed areas may require an inspection or controlled opening-up, with the necessary permissions.

Where the pipework can run

  • Within the floor build-up: check the depth available for services and finishes. Do not assume the structural floor can be cut into.
  • Within walls or service linings: these can accommodate pipework but reduce usable room width and must provide the necessary access.
  • Above suspended ceilings: this may be useful for pressurised water supply pipes. Wastewater from a backwash basin cannot rise to the ceiling of the same premises by gravity. Routing drainage through the ceiling space of the storey below requires checks on levels, access, ownership and permissions.
  • Within raised service platforms: these can create sufficient height for drainage, but introduce level changes and affect circulation, accessibility and clear headroom.

Coordinate these decisions with the structure, electrical services, fire safety and the building’s constraints. Drilling through beams, altering shared building elements or using space belonging to someone else requires prior assessment and any necessary authorisation.

Simultaneous demand: how many fixtures run together, and for how long?

Counting fixtures is not enough. Two salons with four backwash basins may have different demands if one staggers washes while the other regularly carries out several rinses at once. It also matters whether those uses coincide with a washing machine filling, a utility sink running or water-connected beauty equipment operating.

A water heater produces hot water; it is not an additional point of use to count as though it were another basin. It takes in cold water to replace the hot water drawn off and creates an energy demand. A cold-fill washing machine does not use the salon’s domestic hot water supply, although it can draw water and electricity at the same time as other equipment. Check the specifications of hot-and-cold-fill appliances and beauty equipment individually.

Simultaneous use has two separate implications:

  • Instantaneous demand: several open taps require adequate flow, available pressure and correctly sized shared pipework. An undersized system can lose performance during a treatment.
  • Sustained demand: consecutive washes can exhaust the hot water reserve even when each tap works properly. Storage capacity and recovery rate both matter.

Temperature stability also depends on the heater and the taps or mixers. A compatible thermostatic mixer can help regulate temperature, but it cannot compensate for insufficient hot water production or every pressure imbalance.

Describe the expected operation: staff working at the same time, basins used together, actual running-water time and consecutive services during peak periods. The time a client spends in the chair is not the same as the time the water is running.

Choosing hot water equipment: demand and recovery, not just tank size

How to prepare a useful demand estimate

Gather the flow rate specified by the basin or tap manufacturer, the intended water temperature, rinsing times and the concentration of appointments. Include other hot water uses and any planned expansion.

A professional can then estimate mixed-water consumption during the peak period and the share that the hot water system must provide, allowing for the incoming cold water temperature. A tank’s nominal capacity is not the same as the usable volume of mixed water available at the basin. Without these inputs, recommending a fixed tank size would be unreliable.

Storage water heaters

Storage heaters hold a reserve of hot water that can meet short bursts of demand. Selection should consider both that reserve and the heating and recovery times between services. A larger tank takes up more space and needs suitable support for its filled weight, maintenance access and provision for the equipment’s connections and discharge arrangements.

They are worth assessing where there is space for the equipment and the operating pattern matches its capacity and recovery rate. Do not assume an existing domestic water heater will be sufficient for salon use.

Instantaneous water heaters

Instantaneous systems heat water as it is used. Their limit is the flow they can deliver at the required temperature rise. With electric models, supplying several basins may require an electrical capacity and supply arrangement that the premises do not currently have.

The assessment should also account for hairdryers, air conditioning and other electrical loads operating simultaneously. If a combustion-based system is considered, its fuel supply, ventilation and flue requirements must also be addressed.

A central system serving several basins

One shared system can supply the whole wash area and concentrate maintenance in a designated service space. It may use storage, instantaneous heating or a combination: “centralised” describes how the service is organised, rather than a separate heating technology.

Assess the equipment space, distribution routes and the effect of a breakdown on the whole salon. If you intend to use a communal building system, confirm that the proposed use and demand are permitted and supported.

Distance, waiting time and heat loss

Locating the heater farther away can leave more water cooling in the pipes between uses, increasing the wait and the water wasted before a comfortable temperature reaches the basin. Insulation reduces heat loss but does not eliminate that waiting time on its own.

Check whether a hot water return or recirculation circuit is appropriate or required under the applicable design rules. This means allowing space for additional pipework, controls and equipment. Production, storage and delivery temperatures must be set with safety and hygiene in mind; they should not be improvised to make the tank last longer.

Drainage routes can determine where the basins fit

Gravity drainage needs a route compatible with the available difference in level. A longer run may need more vertical space to maintain the designed fall. If it cannot fit beneath the finishes, compare a different basin location, an alternative route or a different construction solution.

Alongside pipe diameter and fall, the design must address changes of direction, drainage ventilation, water-seal traps and access for inspection and clearing blockages. A long run does not automatically mean poor performance, but it needs suitable design and installation. A badly resolved route can contribute to blockages, smells, noise or wastewater backing up.

In a salon, consider hair-catching devices compatible with the equipment and easy access for cleaning. An access point hidden behind fixed cabinetry can turn a routine maintenance task into dismantling work that disrupts appointments.

If gravity drainage is not feasible, a pumped solution requires a specific assessment. The equipment must be suitable for the wastewater and debris it will handle. Noise, power supply, maintenance and the consequences of a breakdown also need consideration. A pump should not be treated as an automatic justification for putting basins anywhere.

Turning technical constraints into layout and budget decisions

Grouping backwash basins in a wet area is often worth considering when it shortens pipe runs and keeps services accessible. It can also simplify towel and product storage. However, the layout must allow working clearance around each unit according to its design, without narrowing circulation routes or obstructing doors.

A position farther from the drainage stack may be justified by privacy, workflow or better customer circulation. Compare the full cost: pipework, opening-up, raised floor build-ups, reinstatement of finishes, electrical work, maintenance and the floor area no longer available for other uses.

A platform that solves the drainage route may make access harder for clients. Review the whole layout, including the accessible toilet and circulation routes, before approving the design.

Checks to resolve before ordering salon backwash units
Constraint Effect on layout Possible consequence Required check
High or distant drainage connection May require moving the basins closer or raising part of the floor. More building work and potential accessibility conflicts. Levels, actual route and designed fall.
Several simultaneous washes Affects shared pipework and equipment space. Changes to the supply and hot water system. Flow rates, pressure under demand and operating pattern.
Insufficient storage or recovery May require different equipment or more space. Waiting between treatments and additional investment. Peak demand and heater performance.
Distant hot water production Creates longer runs and may require a return circuit. Waiting time, heat loss and additional installation work. Pipe lengths, insulation and applicable requirements.
Structural or shared elements affected May rule out the preferred route. Redesign and additional permissions. Technical inspection and authorisations.
Inaccessible maintenance points Requires changes to furniture or enclosures. More expensive repairs and downtime. Practical access for inspection and cleaning.

Three practical scenarios

These hypothetical examples illustrate decisions. They are not completed projects or technically approved layouts.

1. A small salon with two backwash basins

The premises have an existing toilet nearby and a storage water heater. Grouping both basins close to that area is an option to assess first. However, proximity does not prove that the existing drainage branch can accept the additional discharge or that the heater can support two simultaneous rinses.

Decision: check drainage and supply before reusing the existing installation. A small salon can still experience concentrated peaks in demand.

2. A medium-sized salon with four backwash stations

Several rinses coincide with the washing machine filling at certain times. Even if daily consumption seems moderate, the concentration of services may require changes to the shared supply pipework and hot water system.

Decision: size the installation around a realistic operating pattern. Running the washing machine outside peak periods may help manage demand, but should not conceal an installation that cannot support the treatments the salon intends to offer.

3. The preferred customer area is far from the drainage stack

The owner wants the basins in a bright, quiet part of the premises, but the connection is at the rear. The route crosses a circulation area and the available depth beneath the floor is unknown.

Decision: compare the preferred position with a wet area closer to the connection. If the first option requires raised floors, work affecting other properties or a pumping system, establish those implications before ordering furniture.

Warning signs before leasing or buying the premises

  • The drainage connection cannot be identified or accessed for inspection.
  • There is a history of blockages, smells, leaks or undocumented repairs.
  • The proposed route depends on structural alterations or work in someone else’s space without permission.
  • A raised platform is proposed without checking accessibility, doors and headroom.
  • Someone says the hot water “will be enough” without knowing the equipment and simultaneous demand.
  • The available electrical capacity is undocumented, or an upgrade is assumed without verification.
  • The quote covers only appliance connections, leaving out access, finishes, supporting installations or testing.
  • Previous activity documentation, plans or sufficient information on the suitability of the proposed use are unavailable.

These issues need investigation before committing to the investment. They do not all rule out the premises, but they may change the fit-out cost and expected opening date.

Checklist before buying salon furniture and equipment

  • Measured plan: usable dimensions, columns, doors, level changes, heights and circulation areas.
  • Photographs: incoming supply, meter, isolation valves, water heater, electrical panel, drainage stacks and accessible inspection points.
  • Drainage information: connection location, purpose, material, verified diameter, condition and level.
  • Pipe routes: actual length, bends, crossings and available space for each option.
  • Supply performance: professional checks of flow and pressure under representative operating conditions.
  • Operating pattern: basin numbers, staffing, consecutive services and expected simultaneous uses.
  • Shortlisted equipment specifications: dimensions, connections, flow rate, required pressure, waste outlet, working clearance and maintenance access.
  • Hot water and energy: usable capacity, recovery rate or heating output, available energy supply, location and service access.
  • Documentation: previous activity records, available drawings, lease conditions and any necessary permissions.
  • Design validation and quote: reviewed layout, complete scope of work and planned supply, temperature, leak-tightness and drainage tests before handover.

Mark unknown information as “Not specified” and assign responsibility for checking it. Shortlist models so their technical requirements can inform the design, but confirm the purchase only once their suitability has been established.

Spanish requirements and the recommended decision sequence

The general framework in Spain includes the Código Técnico de la Edificación (CTE), particularly DB HS 4 for water supply and DB HS 5 for drainage. A competent professional must establish how these provisions apply to the specific works. Relevant requirements for thermal systems, electrical installations, accessibility, hygiene and business activity also need checking, alongside regional rules, municipal ordinances and building conditions.

Within Madrid city, the appropriate planning and activity procedure depends on the proposed business and works. Do not assume that the same procedure applies in another municipality, or that a former hair salon automatically satisfies the requirements for your proposal.

The recommended sequence is to inspect the premises, estimate simultaneous demand, verify hot water and drainage, develop the layout, and then make the final basin selection and agree the detailed budget. Each decision should be supported by a suitably qualified professional or installer and, where required, the relevant technical documentation and permissions.

If you are planning a hair salon in the Community of Madrid, contact Maceta y Cortafrío to request an assessment of the premises. Our commercial premises renovation service explains how layout, building services and finishes are coordinated to define the scope of work.

Sources and technical references

Adapted from the Spanish article published on 8 November 2026. Featured image: AI-generated conceptual visualisation, not a completed project or a technically validated layout.

Need this service? See our Commercial Premises Renovations in Madrid page.